Compressor units
Our compressor units units range from 100 CFM to 1800 CFM. All models can be customized according to Customers specifications. All Zone 2 diesel driven compressor units are delivered with JB Group’s own 3GHI Protection™ system and are certified by DNVGL for operation without exhaust flame arresters in Hazardous Areas (Zone 2).
All our Compressor Units are operated by JB Group’s own DECAM™, safety and user-friendly, cost effective human interface. Remote and grid operation options available.
All compressor units can be fully certified in accordance with local requirements such as ATEX, IECEx, NORSOK Z-015, OLF 70, Puwer, GHOST, etc. Also DNVGL-ST-E272 certification and SOLAS compliance is also available on request. All units will be CE marked. The units are certified by a third party (DNVGL) and delivered with full documentation and warranty.
The compressor units are capable of operating in ambient temperatures from –20° C to +50° C depending of the design chosen. Lifting frame/container are designed and approved in accordance with DNVGL-ST-E271 and EN 12079. Frames are sandblasted and painted in compliance with offshore specifications in NORSOK M-501. Units can be stacked in height during operation, storage or boat transportation with the use of ISO locks.
Many variations in diesel and electric drive available.
![IMG 6955 white container](https://b3072740.smushcdn.com/3072740/wp-content/uploads/2019/01/IMG_6955.jpg?lossy=2&strip=1&webp=1)
JBWS CU 800 diesel driven, ATEX Zone 2, NORSOK, Z-015, SOLAS, rig water cooled and 74 dBA SPL.
Some of our available designs DIESEL:
- CU 100: 100 CFM @ 10BAR, 3m³/min @ 10BAR, diesel driven, Zone 2.
- CU 200: 200 CFM @ 10BAR, 5m³/min @ 10BAR, diesel driven, Zone 2.
- CU 300: 300 CFM @ 10BAR, 9m³/min @ 10BAR, diesel driven, Zone 2.
- CU 400: 400 CFM @ 10BAR, 12m³/min @ 10BAR, diesel driven, Zone 2.
- CU 500: 500 CFM @ 10BAR, 15m³/min @ 10BAR, diesel driven, Zone 2.
- CU 600: 600 CFM @ 10BAR, 17m³/min @ 10BAR, diesel driven, Zone 2.
- CU 700: 700 CFM @ 10BAR, 20m³/min @ 10BAR, diesel driven, Zone 2.
- CU 800: 800 CFM @ 10BAR, 23m³/min @ 10BAR, diesel driven, Zone 2.
- CU 900: 900 CFM @ 10BAR, 25m³/min @ 10BAR, diesel driven, Zone 2.
- CU 1000: 1000 CFM @ 10BAR, 28m³/min @ 10BAR, diesel driven, Zone 2.
- CU 1100: 1100 CFM @ 10BAR, 31m³/min @ 10BAR, diesel driven, Zone 2.
- CU 1200: 1200 CFM @ 10BAR, 34m³/min @ 10BAR, diesel driven, Zone 2.
- CU 1300: 1300 CFM @ 10BAR, 37m³/min @ 10BAR, diesel driven, Zone 2.
- CU 1400: 1400 CFM @ 10BAR, 40m³/min @ 10BAR, diesel driven, Zone 2.
- CU 1500: 1500 CFM @ 10BAR, 43m³/min @ 10BAR, diesel driven, Zone 2.
- CU 1600: 1600 CFM @ 10BAR, 45m³/min @ 10BAR, diesel driven, Zone 2.
- CU 1700: 1700 CFM @ 10BAR, 48m³/min @ 10BAR, diesel driven, Zone 2.
- CU 1800: 1800 CFM @ 10BAR, 50m³/min @ 10BAR, diesel driven, Zone 2.
Some of our available designs ELECTRICAL:
- CU 100E: 100 CFM @ 10BAR, 3m³/min @ 10BAR, electrical driven, Zone 2.
- CU 200E: 200 CFM @ 10BAR, 5m³/min @ 10 barg, electrical driven, Zone 2.
- CU 300E: 300 CFM @ 10BAR, 9m³/min @ 10 barg, electrical driven, Zone 2.
- CU 400E: 400 CFM @ 10BAR, 12m³/min @ 10 barg, electrical driven, Zone 2.
- CU 500E: 500 CFM @ 10BAR, 15m³/min @ 10 barg, electrical driven, Zone 2.
![CU 900 CU 900](https://b3072740.smushcdn.com/3072740/wp-content/uploads/2019/01/CU-900.jpg?lossy=2&strip=1&webp=1)
Inside JBWS CU 900 diesel driven, ATEX Zone 2, NORSOK, Z-015.
![CU 900 2 CU 900](https://b3072740.smushcdn.com/3072740/wp-content/uploads/2019/01/CU-900_2.jpg?lossy=2&strip=1&webp=1)
JBWS CU 900 diesel driven, ATEX Zone 2, NORSOK, Z-015.